Multimeter Specifications:
|
Maximum voltage between any terminal
and earth ground |
600 V
|
| Surge protection |
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
|
| Display |
Digital: 6,000 counts, updates 4 per second |
| Bar graph |
33 segments, updates 32 per second |
| Operating Temperature |
-10 °C to + 50 °C |
| Storage Temperature |
-40 °C to + 60 °C |
| Battery type |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
| Battery Life |
400 hours typical, without backlight |
Multimeter Accuracy Specifications: |
| DC millivolts |
Range:
Resolution:
Accuracy:
|
600.0 mV
0.1 mV
± ([% of reading] + [counts]): 0.5% + 2 |
| DC volts |
Range/Resolution:
Range/Resolution:
Range/Resolution:
Accuracy: |
6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
± ([% of reading] + [counts]): 0.5% + 2 |
| Auto volts |
Range:
Resolution:
Accuracy:
|
600.0 V
0.1 V
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
|
| AC millivolts {1} true-rms |
Range:
Resolution:
Accuracy:
|
600.0 mV
0.1 mV
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
| AC volts {1} true-rms |
Range/Resolution:
Range/Resolution:
Range/Resolution:
Accuracy:
|
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
| Continuity |
Range:
Resolution:
Accuracy:
|
600 Ω 1 Ω
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer |
| Ohms |
Range/Resolution:
Range/Resolution:
Range/Resolution:
Range/Resolution:
Range/Resolution:
Accuracy:
Range/Resolution:
Accuracy: |
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
0.9 % + 1
40.00 MΩ / 0.01 MΩ
1.5 % + 2 |
| Diode Test |
Range/Resolution:
Accuracy: |
2.000 V / 0.001 V
0.9% + 2 |
| Capacitance |
Range/Resolution:
Range/Resolution:
Range/Resolution:
Range/Resolution:
Range/Resolution:
Accuracy:
Range/Resolution:
Accuracy: |
1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
1.9% + 2 > 1000 μF
5% + 20% |
| LoZ capacitance |
Range:
Accuracy: |
1 nF to 500 μF
10% + 2 typical |
Temperature {2}
(Type-K thermocouple) |
Range/Resolution:
Accuracy:
Range/Resolution:
Accuracy: |
-40 °C to 400 °C / 0.1 °C
1% + 10 {2}
-40 °F to 752 °F / 0.2 °F
1% + 18 {2}
|
AC μamps true-rms
(45 Hz to 500 Hz) |
Range/Resolution:
Accuracy: |
600.0 μA / 0.1 μA
1.0% + 2 |
| DC μamps |
Range/Resolution:
Accuracy: |
600.0 μA / 0.1 μA
1.0% + 2 |
| Hz (V or A input){2} |
Range/Resolution:
Range/Resolution:
Range/Resolution:
Range/Resolution:
Accuracy: |
99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
0.1% + 2 |
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
|
Thermometer Specifications:
|
Measurement range |
-30 °C to 500 °C (-20 °F to 932 °F)
|
| Accuracy |
10 ºC to 30 ºC (50 ºF to 86 ºF): ± 1 ºC (2 ºF)
Outside 10 ºC to 30 ºC (50 ºF to 86 ºF): ± 1.5 ºC (3 ºF) or ± 1.5 % of reading, whichever is greater
|
| Repeatability |
Digital: 6,000 counts, updates 4 per second |
| Emissivity |
33 segments, updates 32 per second |
| Response time |
-10 °C to + 50 °C |
| Distance to spot size |
-40 °C to + 60 °C |
| Spectral range |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
| Display resolution |
400 hours typical, without backlight |
| Display hold (7 seconds) |
• |
| LCD backlit |
• |
Temperature display
|
°C or °F selectable |
| Ambient operating range |
0 to 50 °C (32 to 120 °F) |
| Relative humidity |
10-90 % RH non-condensing, @ up to 30 °C (86 °F) |
| Typical distance to target (spot) |
Up to 2 m (6 ft) |
| Laser class II |
Single offset laser |
| Weight/dimensions |
200 g (7 oz); 152 x 101 x 38 mm (6 x 4 x 1.5 in) |
| Power |
9 V Alkaline battery (included) |
| Battery life (alkaline) |
12 hours |
| Storage temperature |
-20 ºC to 65 ºC (-4 ºF to 150 ºF) without battery |
| Options/accessories |
Includes protective boot and storage holster |
| Warranty: |
2 years (conditional) |